Module 1 Lab Companion
Tissue Culture Fundamentals
Course: MICR 240 / BIOL 275L | Kapi'olani Community College | Combined Curriculum Module
Exercises 1 – 9 | Weeks 1–4
This Lab Companion guides you through the foundational exercises of MICR 240. Each exercise builds practical skills essential for all subsequent laboratory work. Exercises are presented in sequence and designed to be completed in order.
Safety First: All exercises require a lab coat, gloves, and closed-toed shoes. Never eat or drink in the laboratory. Disinfect your bench with 70% alcohol before and after every session. Report any accidents immediately to the instructor.
Exercise 1: Laboratory Safety & Laboratory Rules
Objective: Familiarize yourself with the rules, emergency equipment locations, and safety procedures for our cell biology and tissue culture laboratory.
Laboratory Rules
NEVER eat, drink, or smoke in the laboratory. Do not bring food or beverages into the lab.
Use 70% alcohol (ethyl or isopropyl) to disinfect your work area at the beginning and end of every lab period. Disinfect gloved hands before beginning work. CAUTION: Alcohol is flammable — keep away from open flames.
If you spill any microorganisms or culture supernatants, cover the area with paper towels, pour disinfectant over them, wait several minutes, then clean up with fresh towels. Always notify your instructor of accidents.
Familiarize yourself with alcohol lamp and Bunsen burner safety. Tie back long hair; secure loose clothing before using flame.
Know the location of: FIRE EXTINGUISHER, FIRE BLANKET, EMERGENCY SHOWER, EYE-WASH STATION, and FIRST AID KIT.
Report any injury — no matter how minor — to the instructor immediately.
Segregate waste: sharps (needles, broken glass, pipettes) go in sharps containers; biological waste in labeled biohazard bags. Do NOT mix contaminated and non-contaminated waste.
Wear CLOSED-TOED SHOES at all times in the laboratory.
Wear PROTECTIVE EYEWEAR for any procedure involving splash hazard.
Wear a LAB COAT and GLOVES while working in the lab.
Lab Notebook Assignment
In your lab notebook, record:
Location of each piece of emergency equipment in our lab.
The three categories of biological waste and how each is discarded at KCC.
The name and concentration of our bench disinfectant.
Exercise 2: Microscopy and Simple Staining
Objective: Learn to operate a compound light microscope correctly, including Köhler illumination. Practice basic staining techniques.
Key Microscope Components
| Component | Function |
|---|---|
| Ocular lenses (eyepieces) | Magnify the image from the objective; typically 10× |
| Objective lenses | Primary magnification: 4× (scan), 10× (low), 40× (high dry), 100× (oil immersion) |
| Stage and XY control | Holds slide; allows precise positioning |
| Condenser and iris diaphragm | Focuses light onto specimen; iris controls light cone angle (resolution) |
| Field iris diaphragm | Controls field illumination; used during Köhler alignment |
| Fine and coarse focus knobs | Adjust objective-to-specimen distance |
| Light source (LED/halogen) | Provides illumination; intensity adjustable |
Köhler Illumination Procedure
Köhler illumination provides the best contrast and resolution. Always set it up before making critical observations.
Place a prepared slide on the stage and focus with the 10× objective.
Close the field iris diaphragm until you see a small circle of light in the field.
Raise or lower the condenser until the edges of the circle are sharply focused.
Center the circle using the condenser centering screws.
Open the field iris until it just disappears outside the field of view.
Adjust the condenser iris diaphragm for optimal contrast.
Vocabulary
| Term | Definition |
|---|---|
| Parfocal | When one objective is in focus, changing to another objective requires only minor fine adjustment |
| Köhler illumination | Alignment technique that provides even, glare-free illumination for optimal resolution |
| Working distance | Distance between objective front lens and the specimen when in focus (shorter at higher magnification) |
| Depth of field | Thickness of specimen in sharp focus at one time (decreases with higher magnification) |
| Magnification | Total = ocular × objective (e.g., 10× × 40× = 400× total) |
| Resolution | Smallest distance between two points that appear as separate — limit ~0.2 μm for light microscopy |
Lab Notebook Questions
Draw the letter 'e' as seen under the naked eye. Now draw it as seen under 10× (low power). How does the image orientation change?
What is Köhler illumination and why is it important?
When you switch from 10× to 40×, does the image change in brightness? Why?
What is the total magnification when using a 10× eyepiece with a 40× objective?
Exercise 3: The Ubiquity of Microbes — Cultural and Microscopic Characteristics
Objective: Demonstrate that microorganisms are present everywhere in the environment. Learn to distinguish different microbial morphologies by microscopy and cultural characteristics.
Activities
Expose nutrient agar plates to air, skin, and surfaces for defined time periods. Incubate and observe colony morphology (size, color, texture, elevation, margin).
Prepare wet mounts of pond water, soil suspension, or yogurt. Observe under 40× and 100× oil immersion.
Perform a simple stain (crystal violet or safranin) to visualize cell morphology.
Identify: cocci (spherical), bacilli (rod-shaped), spirilli (spiral), and filamentous forms.
Lab Notebook Questions
Describe the colony morphology of at least two different colonies on your exposure plate. Include: size, color, texture, elevation, and margin shape.
Draw and label three different microbial morphologies you observed under the microscope.
Why did we see more colonies on the plate exposed to the skin than to clean air?
How would you distinguish bacteria from yeast under a light microscope?
Exercise 4: Serological Pipettes and Pipette Aids
Objective: Learn to correctly use serological (blow-out) pipettes and pipette aids for accurate volume measurement.
Key Concepts
| Pipette Type | Volumes | Identifying Feature |
|---|---|---|
| 1 mL serological | 0.1–1.0 mL (0.01 mL graduations) | Double-frosted band at top (blow-out) |
| 5 mL serological | 0.5–5.0 mL (0.1 mL graduations) | Double-frosted band at top |
| 10 mL serological | 1.0–10.0 mL (0.1 mL graduations) | Double-frosted band at top |
| 25 mL serological | 1.0–25.0 mL (0.5 mL graduations) | Double-frosted band at top |
Blow-out pipette: Graduations start from the TIP. After draining, blow out the last drop to deliver the full stated volume. This is different from 'to-deliver' (TD) pipettes which do not need blow-out.
Reading a meniscus: For aqueous solutions, read the BOTTOM of the concave meniscus at eye level.
Pre-Lab Questions
How is a serological pipette different from a volumetric pipette?
What is a 'blow-out' pipette and how do you identify one?
Why must you read the meniscus at eye level?
Exercise 5: Quantitative Pipetting, Dilutions, and Spectrophotometry
Objective: Perform accurate serial dilutions and measure absorbance using a spectrophotometer. Understand the relationship between absorbance and concentration (Beer-Lambert Law).
Dilution Concepts
Key Formula: C₁V₁ = C₂V₂
Where C₁ = initial concentration, V₁ = volume taken from initial, C₂ = final concentration, V₂ = final volume.
Dilution Factor (DF) = V_total / V_taken = C₁ / C₂
| Dilution | How to Prepare | Dilution Factor |
|---|---|---|
| 1:10 | 1 mL sample + 9 mL diluent | 10 |
| 1:100 | Two sequential 1:10 dilutions, OR 1 mL + 99 mL | 100 |
| 1:2 (half) | 1 mL sample + 1 mL diluent | 2 |
| 1:5 | 1 mL sample + 4 mL diluent | 5 |
Spectrophotometry — Beer-Lambert Law
A spectrophotometer measures how much light of a specific wavelength is absorbed by a solution.
Beer-Lambert Law: A = εcl
A = Absorbance (OD = optical density)
ε = molar extinction coefficient (constant for a substance)
c = concentration of absorbing substance
l = path length (usually 1 cm)
Relationship: A = 2 – log(%T), so as absorbance increases, %Transmittance decreases.
Protocol: Serial Dilution of Dye Standard
Label 6 microcentrifuge tubes: 1/2, 1/4, 1/8, 1/16, 1/32, blank.
Pipette 500 μL of distilled water (diluent) into each tube.
Add 500 μL of the stock dye solution to tube 1/2; vortex or mix well.
Transfer 500 μL from tube 1/2 to tube 1/4; mix well.
Continue transferring 500 μL through each tube. Tube 'blank' contains water only.
Measure absorbance of each dilution at the appropriate wavelength.
Plot Absorbance (Y-axis) vs. Dilution Factor (X-axis). The graph should be linear.
Lab Notebook Questions
Define optical density (OD). What does it measure?
If the OD of your undiluted sample is 0.800 and you make a 1:10 dilution and measure OD = 0.082, does this make sense? Explain.
At what wavelength would you measure a blue solution? A red solution?
If your spectrophotometer reads 10% Transmittance, what is the OD/Absorbance?
Exercise 6: Dilution Techniques and Calculations
Objective: Master serial dilution calculations used throughout the course. Practice preparing dilutions accurately using volumetric technique.
Serial Dilution Practice Problem
A student has a cell culture at 3 × 10⁷ cells/mL and needs to seed a new flask at 5 × 10⁴ cells/mL in 5 mL total volume.
Required concentration = 5 × 10⁴ cells/mL
Starting concentration = 3 × 10⁷ cells/mL
Total dilution factor needed = 3×10⁷ / 5×10⁴ = 600×
Plan: Make a 1:10 dilution (→ 3×10⁶/mL), then a 1:60 dilution (→ 5×10⁴/mL)
For 1:60 dilution to make 5 mL: V₁ = C₂V₂/C₁ = (5×10⁴ × 5) / 3×10⁶ = 0.083 mL = 83 μL
Add 83 μL of the 1:10 dilution to 4.917 mL of medium → 5 mL at 5×10⁴ cells/mL
Lab Notebook Questions
If you have a solution at 2 mg/mL and you want 0.5 mg/mL in 10 mL, what volume of stock do you add to what volume of diluent?
What is the dilution factor of a 1:100 dilution? Write it as a fraction.
Explain the difference between 'dilution' and 'dilution factor.'
A 1:10 dilution series has 6 steps. What is the final dilution factor? What is the concentration if you started at 1 × 10⁶/mL?
Exercise 7: Dilutions Theory, Problems, and Hemocytometer Counting
Objective: Apply dilution calculations to hemocytometer cell counting. Master the cell counting formula and practice with real data.
Hemocytometer Counting Rules
Count cells in the 5 large (1 mm²) squares: the 4 corner squares and the center square.
Count cells touching the TOP and LEFT boundary lines; do NOT count cells touching the BOTTOM and RIGHT lines.
Count total cells in all 5 squares and calculate the average per square.
Distinguish live cells (clear/refractile under phase contrast) from dead cells (stained blue with trypan blue).
Load exactly 10 μL under each side of the coverslip; do not overfill or underfill.
Full Formula:
Cells/mL (viable) = (Total viable cells in 5 squares / 5) × Dilution Factor × 10⁴
The 10⁴ factor = 1000 (μL to mL conversion) × 10 (depth factor: chamber is 0.1 mm = 1/10 of 1 mm)
Practice Problem (from Study Guide 3)
Problem: A student makes the following dilutions:
1 mL cell suspension + 9 mL buffer = Solution #2 (1:10 dilution)
1 mL of Solution #2 + 99 mL buffer = Solution #3 (1:100 dilution of #2; total 1:1,000)
1 mL of Solution #3 + 1 mL trypan blue = Final sample on hemocytometer (total dilution 1:2,000)
Results: 5 squares counted; total viable cells = 85; total dead cells = 28.
Answers:
Final dilution factor = 10 × 100 × 2 = 2,000
Viable cells in Solution #3 = (85/5) × 2 × 10⁴ = 17 × 2 × 10⁴ = 340,000 = 3.4 × 10⁵ cells/mL
Viable cells in original sample = 3.4 × 10⁵ × 1,000 = 3.4 × 10⁸ cells/mL
Dead cells in original sample = (28/5) × 2,000 × 10⁴ = 5.6 × 2,000 × 10⁴ = 1.12 × 10⁸ cells/mL
% Viability = 3.4×10⁸ / (3.4×10⁸ + 1.12×10⁸) = 3.4 / 4.52 = 75.2% viable
Exercise 8: Micropipettor Use and Care
Objective: Learn to use micropipettors (P20, P200, P1000) correctly for accurate small-volume pipetting.
| Micropipettor | Volume Range | Tip Type | Color Code (typical) |
|---|---|---|---|
| P20 | 2–20 μL | Yellow (10 μL) | Yellow plunger |
| P200 | 20–200 μL | Yellow (200 μL) | Yellow plunger |
| P1000 | 100–1000 μL | Blue (1000 μL) | Blue plunger |
Critical: Never set a micropipettor above its maximum volume — this damages the mechanism. Never pipette without a tip. Hold the pipettor vertically when aspirating for best accuracy.
Proper Pipetting Technique
Set the volume on the display before picking up a tip.
Press the plunger to the FIRST stop. Insert the tip into the liquid.
Slowly release the plunger to aspirate the liquid. Wait 1–2 seconds.
Remove the tip from the liquid. Wipe the outside of the tip if needed.
Place the tip in the receiving vessel. Press to the FIRST stop to dispense.
Continue pressing to the SECOND stop (blow-out position) to expel the last drop.
Eject the tip using the ejector button. Never touch tips with bare hands.
Common Errors: (1) Angled pipetting — causes variable volume. (2) Not pre-wetting the tip for viscous solutions. (3) Touching the tip to vessel wall during aspiration. (4) Too-fast plunger release causing bubbles or splashing.
Exercise 8a: Micropipettor Dilution Series Protocol
Objective: Demonstrate accurate pipetting by preparing a dye dilution series and measuring absorbance.
Label 8 microcentrifuge tubes: 100%, 50%, 25%, 12.5%, 6.25%, 3.125%, 1.56%, 0% (blank).
Add 100 μL of diluent (distilled water) to tubes 50% through 1.56%.
Add 200 μL of dye stock to the 100% tube.
Transfer 100 μL from the 100% tube to the 50% tube; mix by pipetting up and down 5×.
Transfer 100 μL from 50% to 25%; mix well. Continue through 1.56%.
Add 200 μL of water to the blank tube.
Measure absorbance of each tube at the appropriate wavelength.
Record in data table. Plot absorbance vs. dilution percentage.
Data Table
| Tube | Concentration (%) | Dilution Factor | Absorbance (OD) | Notes |
|---|---|---|---|---|
| 100% | 100 | 1 | ||
| 50% | 50 | 2 | ||
| 25% | 25 | 4 | ||
| 12.5% | 12.5 | 8 | ||
| 6.25% | 6.25 | 16 | ||
| 3.125% | 3.125 | 32 | ||
| 1.56% | 1.56 | 64 | ||
| Blank | 0 | — | Diluent only |
Exercise 9: Tissue Culture Media — Preparation and Quality Control
Objective: Prepare complete tissue culture medium from components and check for sterility and correct pH.
Overview
Tissue culture medium must be prepared aseptically. We typically supplement basal medium (e.g., DMEM or RPMI) with serum, antibiotics, and buffering agents before use.
Media Preparation Protocol (Complete DMEM)
Work in the biosafety cabinet. Wipe down interior with 70% ethanol. Turn on UV for 10 min before use.
Remove a bottle of DMEM basal medium from 4°C refrigerator; allow to warm in 37°C water bath for 15–20 min.
In the BSC, open the DMEM bottle using sterile technique.
Using a 50 mL serological pipette, remove 55 mL from the DMEM bottle (to make room for supplements).
Add 50 mL of heat-inactivated fetal bovine serum (FBS, 10% final) — pipette carefully into DMEM bottle.
Add 5 mL of Penicillin-Streptomycin solution (100× stock → 1× final = 100 U/mL Pen + 100 μg/mL Strep).
Cap the bottle and mix gently by inversion 5–10 times.
Label the bottle with: medium type, your initials, date prepared, expiration date (4 weeks at 4°C).
Check color (should be orange-pink = pH 7.2–7.4). If yellow, medium may be acidic — check CO₂ settings.
Store at 4°C. Warm aliquots to 37°C before each use.
Quality Control Checks
| Check | Method | Acceptable Result |
|---|---|---|
| pH (visual) | Phenol red color | Orange-pink (#7.2–7.4); not yellow or purple |
| Sterility | Aliquot 5 mL into blank well plate; incubate 37°C 3 days | No turbidity, no color change |
| Osmolality (optional) | Osmometer reading | 290–310 mOsmol/kg |
Lab Notebook Questions — Exercise 9
What is the purpose of heat-inactivating FBS before adding it to medium?
Why do we warm medium to 37°C before adding it to cells? What might happen if you added cold medium to a flask of cells?
List the three QC checks and explain why each is important.
If your prepared medium turned yellow after 3 days at 4°C, what could explain this?
Why do we label medium bottles with the preparation date and expiration date?